How to Fix a Furnace Pressure Switch Stuck Open

A furnace pressure switch stuck open can prevent your furnace from starting, leading to heating issues in your home. This guide will walk you through the steps to diagnose and fix a furnace pressure switch stuck open, ensuring your furnace operates efficiently.

Step 1: Turn Off the Furnace Safety first! Before attempting any repairs, turn off the power to your furnace. This can usually be done by switching off the furnace at the circuit breaker or using the power switch on the furnace itself.

Step 2: Locate the Pressure Switch The pressure switch is typically located near the inducer motor, which is responsible for creating negative pressure in the furnace. Refer to your furnace’s manual if you’re unsure where to find it.

Step 3: Check the Inducer Motor Ensure that the inducer motor is running properly. If the motor isn’t starting, it can cause the pressure switch to remain open. Listen for the sound of the inducer motor running or check for any visible issues with the motor.

Step 4: Inspect the Pressure Switch Hose The pressure switch hose connects the switch to the inducer motor. Check the hose for any cracks, damage, or disconnections. A damaged hose can prevent the pressure switch from closing.

Step 5: Clean the Pressure Switch and Hose Dirt and debris can accumulate in the pressure switch and hose, causing it to malfunction. Use a soft brush or cloth to clean the switch and hose. You can also use compressed air to blow out any debris.

Step 6: Test the Pressure Switch To test the pressure switch, disconnect the hose from both the switch and the inducer motor. Use a multimeter to check for continuity across the switch terminals. If there’s no continuity, the switch may need to be replaced.

Step 7: Reconnect and Test the Furnace Reconnect the hose and turn the power back on to the furnace. Try starting the furnace again to see if the pressure switch has resolved the issue. If the furnace still doesn’t start, further troubleshooting may be needed.

Step 8: Replace the Pressure Switch (if necessary) If cleaning and testing the pressure switch doesn’t fix the issue, you may need to replace it. Purchase a new pressure switch compatible with your furnace model and follow the manufacturer’s instructions for installation.

Conclusion: Fixing a furnace pressure switch stuck open involves checking the inducer motor, inspecting the pressure switch hose, cleaning the components, and testing for continuity. By following these steps, you can diagnose and resolve the issue, ensuring your furnace operates smoothly.

Categories Fix